| Series MC |
|
Port 1/4", 3/8", 1/2" NPTF Modular with metal bowl guard and bayonet-type mounting The Series MC filters are available with port 1/4", 3/8" or 1/2" NPTF. The bowls of these filters are made of Nylon - Grilamid with an aluminum bowl guard and have a condensate drain valve in five (5) different options. On request it is possible to order filters with filtering elements in different filtration ranges than those listed standard in the code key.
Port 1/4", 3/8" & 1/2" NPTF Modular with metal bowl guard and bayonet-type mounting The Series MC coalescing filters are available with 1/4", 3/8", 1/2" NPTF port. The bowls of these filters are made of Nylon-Grilamid with an aluminum bowl guard and have a condensate drain valve in five (5) different options.
Port 1/4", 3/8", 1/2" NPTF Modular The Series MC pressure regulators are available with port 1/4", 3/8", 1/2" NPTF. Relieving diaphragms are standard. Non-Relieving and Fast-Response Relieving diaphragms are optional, as called out in the code key. All versions can be panel mounted.
Inlet port 1/4" NPTF, full Inlet pressure (non-cascading), 2 outlets per unit. Modular The manifold pressure regulators are available with port 1/4" NPTF. Normally they are available with relieving diaphragm as standard and can be panel mounted.
Examples assembly hardware kits Assembly without end plates. Assembly with end plates.
Port 1/4", 3/8", 1/2" NPTF Modular with metal bowl guard and bayonet-type mounting The Series MC lubricators are available with port 1/4", 3/8", 1/2" NPTF. The bowls of these lubricators are made of metal and are equipped with a transparent viewer. The oil flow can be monitored via the small transparent cap and regulated by means of the special adjusting screw.
Port 1/4", 3/8", 1/2" NPTF Modular with metal bowl guard and bayonet-type mounting The filter regulators Series MC are available with port 1/4", 3/8", 1/2" NPTF. They combine the features of the filters and regulators and have smaller overall dimensions than the two separate components.
Port 1/4", 3/8", 1/2" NPTF Modular The valves are designed so that the downstream air pressure can be vented and the valve locked in the non passing condition to allow work to be carried out with greater safety on pneumatically actuated equipment. Positioning of these valves is often before the FRL unit. Pulling Manual handle in the "UP" direction shuts off inlet flow and exhausts all downstream pressure via the threaded port in the bottom of the unit. (Silencers can be installed to minimize noise). With handle extended "UP", lock-out hole (0.315" OD), is exposed in handle spool for locks or hasps. (Valve shown in illustration in "DOWN" position for normal inlet flow to pass.)
Port 1/4", 3/8", 1/2" NPTF: Model ‘-V16’ has Solenoid Pilot Model ‘-V36’ has Air Pilot Modular These 3/2 way valves are designed to block the air at the inlet of the FRL group to pressurize or depressurize the equipment. The valves can either be electropneumatically or pneumatically operated and can be supplied with port 1/4", 3/8", 1/2" NPTF. In case of a solenoid valve use coil type U7… or G7… and the coil is ordered as a separate item.
Innovative modular clamping system Ports 1/4", 3/8", 1/2" NPTF The Series MC sort start valve is used to avoid damaging people or equipment when pressurizing pneumatic systems containing cylinders. The features of these components allows one to pressurize equipment up to 50% of the set outlet reduced pressure, after which 100% is reached rapidly. The usual location of the soft start valve is after the FRL. The modular design allows for perfect adaptability with all Series MC. A pressure switch can be mounted into the upper part of the unit after removal of the S2610 1/8 plug. An electrical or pneumatic 3 way Shut-Off valve may or may not be installed before the unit to allow Depressurization. The brass adjustment screw in the head cap varies the timing constant and the pressure ramp-up rate.
Ports 1/4", (3/8"), 1/2" NPTF Modular, with or without internal Check-Valve The take-off blocks when equipped with a check-valve, allow the use of non lubricated air from the vertical outlets if inserted between the regulator and the lubricator. Otherwise, the check-valve prevents downstream lubrication from siphoning back upstream where non-lube components may be required. If mounted as last component in a completed assembly, the distribution block requires the use of end-plates since its main horizontal flow path ports are non-threaded. Meaning, no direct threaded components can be assembled in the left-to-right flow path. ONLY end-plates can be used, unless otherwise in the middle of a typical FRL assembly.
Solenoids for FRL Electrical Shut-Off valves (Mod. V16), and electropneumatically operated valves Series A - 3 - 4 - 9 - NA Solenoids for Series “U” solenoid valves DIN Connector for U7x and G7x Coils Solenoids for solenoid valves Mod. U70/G70 Solenoid Voltages U70 Solenoid Voltages G70
Ports 1/4", 3/8", 1/2" NPTF The FRL Series MC Fully Assembled version are easier to order using one single part number code and to mount. The version with end-plate kit flanges is supplied without rear mounting bracket assembly, KIT B, (sold separately).
FRL Series MC Assembly Hardware Kits Example of FRL modular assembly.
Mounting Brackets Accessories and Kits Terminal flanges Series MC (Kit A). Mounting bracket, Series MC - M - N. Mounting bracket Series MC - M - N. Mounting bracket Series MC (Kit B). Screw for assembling, Series MC (Kit E). Pressure gauges Mod. M043-P04TF (0 - 60 psi) Pressure gauges Mod. M043-P10TF (0 - 160 psi). Screw for assembling, Series MC (Kit F). Tie-rod for assembling, Series MC (Kit C). Tie-rod for assembling Series MC (Kit D). Assembly O-ring, Series C - MC. Tie-rod for assembling, Series MC (Kit G).
Semi-automatic - manual drain - option Type “F*0” Automatic drain - option Type “F*3” Depressurization drain (“spitter” drain) - option Type “F*4” Depressurization drain, protected - option Type “F*5” 1/8" port (without drain) - option Type “F*8” Semi-automatic - manual drain “F*0” Type |